William Paul Segars
Radiology
Professor in Radiology
Bio
Our current research involves the use of computer-generated phantoms and simulation techniques to investigate and optimize medical imaging systems and methods. Medical imaging simulation involves virtual experiments carried out entirely on the computer using computational models for the patients as well as the imaging devices. Simulation is a powerful tool for characterizing, evaluating, and optimizing medical imaging systems. A vital aspect of simulation is to have realistic models of the subject's anatomy as well as accurate models for the physics of the imaging process. Without this, the results of the simulation may not be indicative of what would occur in actual clinical studies and would, therefore, have limited practical value. We are leading the development of realistic simulation tools for use toward human and small animal imaging research.
These tools have a wide variety of applications in many different imaging modalities to investigate the effects of anatomical, physiological, physical, and instrumentational factors on medical imaging and to research new image acquisition strategies, image processing and reconstruction methods, and image visualization and interpretation techniques. We are currently applying them to the field of x-ray CT. The motivation for this work is the lack of sufficiently rigorous methods for optimizing the image quality and radiation dose in x-ray CT to the clinical needs of a given procedure. The danger of unnecessary radiation exposure from CT applications, especially for pediatrics, is just now being addressed. Optimization is essential in order for new and emerging CT applications to be truly useful and not represent a danger to the patient. Given the relatively high radiation doses required of current CT systems, thorough optimization is unlikely to ever be done in live patients. It would be prohibitively expensive to fabricate physical phantoms to simulate a realistic range of patient sizes and clinical needs especially when physiologic motion needs to be considered. The only practical approach to the optimization problem is through the use of realistic computer simulation tools developed in our work.
Education
- Ph.D. University of North Carolina, Chapel Hill, 2001
Positions
- Professor in Radiology
- Professor of Biomedical Engineering
Awards, Honors, and Distinctions
- Farrington Daniels Award. American Association of Physicists in Medicine. 2013
Publications
- Tattenberg S, Hands A, Bu00e9langer-Champagne C, Johnstone C, Segars WP, Minchinton A, et al. Dosimetric comparability validation of small animal photon and neutron irradiations. J Radiol Prot. 2026 Jan 16;46(1).
- Gomez JT, Nadkarni N, Bosma LS, Jiang J, Subashi ED, Segars WP, et al. Modality-agnostic, patient-specific digital twins modeling temporally varying digestive motion. Phys Med Biol. 2026 Jan 6;71(1).
- Subramanian S, Segars WP, Faria AV, Lee T-Y, Taguchi K. Intra-operative soft tissue perfusion assessment using X-ray angiography images: ischemic stroke study. Med Phys. 2026 Jan;53(1):e70281.
- Pijanowski J, Pretorius PH, Segars WP, Pells S, Cao X, Ljungberg M, et al. A data-driven respiratory motion correction for pediatric DMSA renal SPECT imaging: A simulation study. Med Phys. 2026 Jan;53(1):e70279.
- Mouheb K, Nejad MG, Dahal L, Samei E, Lafata KJ, Segars WP, et al. Large Intestine 3D Shape Refinement Using Conditional Latent Point Diffusion Models. In: Lecture Notes in Computer Science. 2026. p. 103u201316.
- Bhattarai M, Panta RK, Segars WP, Abadi E, Samei E. Development of a customizable model for spectral photon-counting detector CT. Med Phys. 2025 Dec;52(12):e70195.
- Rajagopal JR, Rapaka S, Farhadi F, Abadi E, Segars WP, Nowak T, et al. Development of a deep learning based approach for multi-material decomposition in spectral CT: a proof of principle in silico study. Sci Rep. 2025 Aug 6;15(1):28814.
- Fu W, Sharma S, Solomon J, Ria F, Setiawan H, Ding A, et al. Patient-specific organ dose and in-vivo image quality assessment in clinical CT. Phys Med. 2025 Aug;136:105017.
- Segars HE, Nadkarni R, Badea CT, Badea A, Chin B, Johnson GA, et al. Development of anatomically variable digital Wistar rat phantoms for small animal imaging research. Med Phys. 2025 Aug;52(8):e18057.
- Kavuri A, Paul Segars W, Xu X, Lynch DA, Page McAdams H, Samei E, et al. Effects of Intra-patient Lung Volume Variability on CT-Based Emphysema Quantification: Au00a0Virtual Imaging Study. Acad Radiol. 2025 Aug;32(8):4913u201321.
- Salinas CS, Magudia K, Sangal A, Ren L, Segars WP. In-silico CT simulations of deep learning generated heterogeneous phantoms. Biomed Phys Eng Express. 2025 Jul 10;11(4).
- Obaid M, Rahmim A, Segars WP, Brosch-Lenz J, Uribe C. S-values for bone marrow dosimetry in preclinical radiopharmaceutical studies with rodents. EJNMMI Phys. 2025 Jul 8;12(1):67.
- Malin EJ, Ceritoglu C, Abadi E, Ratnanather JT, Samei E, Segars WP. Library of realistic 4D digital beating heart models based on patient CT data. Med Phys. 2025 Jul;52(7):e17945.
- Salinas CS, Segars WP, Samei E, Magudia K. Transforming body composition of computational phantoms based on form-finding dynamics. Med Phys. 2025 Jul;52(7):e17935.
- Dahal L, Ghojoghnejad M, Vancoillie L, Ghosh D, Bhandari Y, Kim D, et al. XCAT 3.0: A comprehensive library of personalized digital twins derived from CT scans. Med Image Anal. 2025 Jul;103:103636.
- Tushar FI, Vancoillie L, McCabe C, Kavuri A, Dahal L, Harrawood B, et al. Virtual lung screening trial (VLST): An in silico study inspired by the national lung screening trial for lung cancer detection. Med Image Anal. 2025 Jul;103:103576.
- Taguchi K, Subramanian S, Faria AV, Segars WP. Volumetric soft tissue perfusion assessment on a region basis from x-ray angiography images: Motion compensation. Med Phys. 2025 Jun;52(6):3785u201399.
- Tushar FI, Vancoillie L, McCabe C, Kavuri A, Dahal L, Harrawood B, et al. Virtual Lung Screening Trial (VLST): An In Silico Study Inspired by the National Lung Screening Trial for Lung Cancer Detection. ArXiv. 2025 Apr 4;
- Abadi E, Segars WP, Felice N, Sotoudeh-Paima S, Hoffman EA, Wang X, et al. AAPM Truth-based CT (TrueCT) reconstruction grand challenge. Med Phys. 2025 Apr;52(4):1978u201390.
- Samei E, Abadi E, Bakic P, Bliznakova K, Bosmans H, Carton A-K, et al. Virtual imaging trials in medicine: A brief takeaway of the lessons from the first international summit. Med Phys. 2025 Mar;52(3):1950u20139.
- McCabe C, Abadi E, Zarei M, Segars WP, Samei E. The potential of photon-counting CT for the improved precision of lung nodule radiomics. Phys Med Biol. 2025 Jan 27;70(3).
- Taguchi K, Subramanian S, Faria AV, Segars WP. Can we assess brain perfusion even when DSA images are contaminated by motion artifacts? In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2025.
- Felice N, Segars WP, Samei E. A Monte Carlo model of coronary artery plaque growth for use in computational phantoms. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2025.
- Olivas K, Byrd DW, Felice N, Segars WP, Kinahan PE, Abadi E, et al. An integrated PET-CT simulation pipeline for biomedical imaging research. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2025.
- Salinas CS, Magudia K, Sangal A, Ren L, Samei E, Segars WP. 3D CTGAN: generating 3D heterogeneous tissue textures for virtual phantoms. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2025.
- Malin E, Hoejimaker M, Goddard C, Sommer CM, Huang CJ, Bryan R, et al. Efficient Formation of Patient-Specific Finite-Element Models of the Heart. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2025.
- Nadkarni R, Clark DP, Allphin AJ, Qi Y, Mowery YM, Segars WP, et al. Development of a Virtual Photon-Counting Micro-CT Imaging Platform for Preclinical Cancer Studies. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2025.
- Wildman-Tobriner B, Felice N, Kalisz KR, Allen BC, Thomas SP, Kruse DE, et al. Photon-Counting CT Effects on Sensitivity for Liver Lesion Detection: A Reader Study Using Virtual Imaging. Radiology. 2025 Jan;314(1):e241568.
- Davey M, Puelz C, Rossi S, Smith MA, Wells DR, Sturgeon GM, et al. Simulating cardiac fluid dynamics in the human heart. PNAS Nexus. 2024 Oct;3(10):pgae392.
- Feiger B, Jensen CW, Bryner BS, Segars WP, Randles A. Modeling the effect of patient size on cerebral perfusion during veno-arterial extracorporeal membrane oxygenation. Perfusion. 2024 Oct;39(7):1295u2013303.
- Felice N, Wildman-Tobriner B, Segars WP, Bashir MR, Marin D, Samei E, et al. Photon-counting computed tomography versus energy-integrating computed tomography for detection of small liver lesions: comparison using a virtual framework imaging. J Med Imaging (Bellingham). 2024 Sep;11(5):053502.
- Yamaguchi S, Tanaka R, Matsumoto I, Ohkura N, Segars WP, Abadi E, et al. Estimation of threshold thickness of residual normal tissue in lung dysfunction detectable by dynamic chest radiography: A virtual imaging trial. Med Phys. 2024 Sep;51(9):5978u201389.
- Aghapanah H, Rasti R, Kermani S, Tabesh F, Banaem HY, Aliakbar HP, et al. CardSegNet: An adaptive hybrid CNN-vision transformer model for heart region segmentation in cardiac MRI. Comput Med Imaging Graph. 2024 Jul;115:102382.
- Tanade C, Felice N, Samei E, Randles A, Segars WP. Enhanced CT simulation using realistic vascular flow dynamics. Medical Imaging 2024 - Physics of Medical Imaging. 2024 Apr 1;12925:399u2013404.
- Sotoudeh-Paima S, Segars WP, Ghosh D, Luo S, Samei E, Abadi E. A systematic assessment and optimization of photon-counting CT for lung density quantifications. Med Phys. 2024 Apr;51(4):2893u2013904.
- Sauer TJ, Buckler AJ, Abadi E, Daubert M, Douglas PS, Samei E, et al. Development of physiologically-informed computational coronary artery plaques for use in virtual imaging trials. Med Phys. 2024 Mar;51(3):1583u201396.
- Sotoudeh-Paima S, Ho FC, Nejad MG, Kavuri A, Ou2019Sullivan-Murphy B, Lynch DA, et al. Development and Application of a Virtual Imaging Trial Framework for Longitudinal Quantification of Emphysema in CT. Proc SPIE Int Soc Opt Eng. 2024 Feb;12925.
- Kavuri A, Ho FC, Ghojogh-Nejad M, Sotoudeh-Paima S, Samei E, Segars WP, et al. Quantitative accuracy of lung function measurement using parametric response mapping: A virtual imaging study. In: Proc SPIE Int Soc Opt Eng. 2024.
- Yang D, Segars WP, Wu QJ, Sheng Y. Lung Cancer Computed Tomography Synthesis with Denoising Diffusion Probabilistic Models. In: MEDICAL PHYSICS. 2024. p. 7756u20137756.
- Bloom LH, Craciunescu OI, Venkarataman R, Kim Y, Segars WP, Ayala-Peacock D, et al. Investigation of Deformable Registration Accuracy for a Real-Time TRUS Needle Tracking System for GYN HDR Brachytherapy. In: MEDICAL PHYSICS. 2024. p. 7797u20137797.
- Panta RK, Yin Z, Gronberg F, Bhattarai M, Abadi E, Segars WP, et al. Accurate Iodine Quantification Via Deep Silicon Photon-Counting CT: Size, Dose, Concentration, and Organ Dependencies. In: MEDICAL PHYSICS. 2024. p. 7715u20137715.
- Stevens JB, Mowery YM, Brizel D, Liu JG, Segars WP, Lafata K. In-Silico Tumor Modeling and Digital Twins of Oropharyngeal Cancer Based on Assimilation of Mathematical Biology and Clinical Imaging. In: MEDICAL PHYSICS. 2024. p. 6608u20139.
- Bhattarai M, Panta RK, Clark D, Segars WP, Abadi E, Samei E. A generic model of semiconductor-based photon-counting detectors for spectral CT. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2024.
- Tushar FI, Vancoillie L, McCabe C, Kavuri A, Dahal L, Harrawood B, et al. Virtual NLST: Towards Replicating National Lung Screening Trial. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2024.
- Goshima F, Tanaka R, Matsumoto I, Ohkura N, Abe T, Segars WP, et al. Deep learning-based algorithm to segment pediatric and adult lungs from dynamic chest radiography images using virtual patient datasets. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2024.
- Subramanian S, Segars WP, Lee TY, Faria AV, Lee D, Unberath M, et al. A CT system-free Approach for Brain CT Perfusion Assessment: Temporal Perfusion Index Estimation. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2024.
- Kim D, Dahal L, Lo JY, Yeom YS, Kim CH, Segars WP. Random Walk Small Intestine Models for Virtual Patient Populations. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2024.
- McCabe C, Solomon J, Segars WP, Abadi E, Samei E. Synthesizing heterogeneous lung lesions for virtual imaging trials. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2024.
- Sauer TJ, McCabe C, Abadi E, Samei E, Segars WP. Surface-based anthropomorphic bone structures for use in high-resolution simulated medical imaging. Phys Med Biol. 2023 Dec 28;69(1).
- Zarei M, Abadi E, Segars WP, Samei E. Coronary stenosis quantification in cardiac computed tomography angiography: multi-factorial optimization of image quality and radiation dose. J Med Imaging (Bellingham). 2023 Nov;10(6):063502.
- Abadi E, Jadick G, Lynch DA, Segars WP, Samei E. Emphysema Quantifications With CT Scan: Assessing the Effects of Acquisition Protocols and Imaging Parameters Using Virtual Imaging Trials. Chest. 2023 May;163(5):1084u2013100.
- McCabe C, Sauer TJ, Zarei M, Segars WP, Samei E, Abadi E. A systematic assessment of photon-counting CT for bone mineral density and microarchitecture quantifications. Proc SPIE Int Soc Opt Eng. 2023 Feb;12463.
- Ho FC, Sotoudeh-Paima S, Segars WP, Samei E, Abadi E. Development and Application of a Virtual Imaging Trial framework for Airway Quantifications via CT. Proc SPIE Int Soc Opt Eng. 2023 Feb;12463.
- Hu00e4ggmark I, Shaker K, Nyru00e9n S, Al-Amiry B, Abadi E, P Segars W, et al. Phase-contrast virtual chest radiography. Proc Natl Acad Sci U S A. 2023 Jan 3;120(1):e2210214120.
- Dahal L, Wang Y, Tushar FI, Montero I, Lafata K, Abadi E, et al. Automatic quality control in computed tomography volumes segmentation using a small set of XCAT as reference images. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2023.
- Goshima F, Tanaka R, Segars WP, Abadi E, Samei E. Bone suppression technique for multidirectional dynamic chest radiography: A virtual imaging trial. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2023.
- Silva CCO, da Silva AX, Braz D, Lima LFC, Segars WP, de Su00e1 LV. S-values for radium-223 and absorbed doses estimates for 223RACL2 using three computational phantoms. Appl Radiat Isot. 2022 Nov;189:110387.
- Chen J, Frey EC, He Y, Segars WP, Li Y, Du Y. TransMorph: Transformer for unsupervised medical image registration. Med Image Anal. 2022 Nov;82:102615.
- Fedrigo R, Segars WP, Martineau P, Gowdy C, Bloise I, Uribe CF, et al. Development of scalable lymphatic system in the 4D XCAT phantom: Application to quantitative evaluation of lymphoma PET segmentations. Med Phys. 2022 Nov;49(11):6871u201384.
- Wu M, FitzGerald P, Zhang J, Segars WP, Yu H, Xu Y, et al. XCIST-an open access x-ray/CT simulation toolkit. Phys Med Biol. 2022 Sep 28;67(19).
- Taguchi K, Polster C, Segars WP, Aygun N, Stierstorfer K. Model-based pulse pileup and charge sharing compensation for photon counting detectors: A simulation study. Med Phys. 2022 Aug;49(8):5038u201351.
- Sharma S, Kapadia A, Ria F, Segars WP, Samei E. Dose coefficients for organ dosimetry in tomosynthesis imaging of adults and pediatrics across diverse protocols. Med Phys. 2022 Aug;49(8):5439u201350.
- Sugiura T, Tanaka R, Samei E, Segars WP, Abadi E, Kasahara K, et al. Quantitative analysis of changes in lung density by dynamic chest radiography in association with CT values: a virtual imaging study and initial clinical corroboration. Radiol Phys Technol. 2022 Mar;15(1):45u201353.
- Sharma S, Kapadia A, Brown J, Segars WP, Bolch W, Samei E. A GPU-accelerated framework for individualized estimation of organ doses in digital tomosynthesis. Med Phys. 2022 Feb;49(2):891u2013900.
- Fu W, Sharma S, Abadi E, Iliopoulos A-S, Wang Q, Lo JY, et al. Corrections to "iPhantom: A Framework for Automated Creation of Individualized Computational Phantoms and its Application to CT Organ Dosimetry". IEEE J Biomed Health Inform. 2022 Jan;26(1):478.
- Dahal L, Tushar FI, Abadi E, Fricks RB, Mazurowski M, Segars WP, et al. Virtual versus reality: external validation of COVID-19 classifiers using XCAT phantoms for chest radiography. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2022.
- Tanaka R, Segars WP, Abadi E, Minami S, Samei E. Optimization of imaging conditions in pediatric dynamic chest radiography: a virtual imaging trial. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2022.
- Clark DP, Abadi E, Felice N, Segars WP, Samei E, Badea CT. Cardiac CT reconstruction for vendor-neutral virtual imaging trials. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2022.
- Sotoudeh-Paima S, Segars WP, Samei E, Abadi E. Photon-counting CT versus conventional CT for COPD quantifications: intra-scanner optimization and inter-scanner assessments using virtual imaging trials. Proc SPIE Int Soc Opt Eng. 2022;12031.
- Abadi E, McCabe C, Harrawood B, Sotoudeh-Paima S, Segars WP, Samei E. Development and Clinical Applications of a Virtual Imaging Framework for Optimizing Photon-counting CT. Proc SPIE Int Soc Opt Eng. 2022;12031.
- Bhattarai M, Sharma S, Vrbau0161ki S, Abadi E, Segars WP, Contillo A, et al. Simulation of the combined effects of charge sharing and pulse pileup in photon-counting CT. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2022.
- Tushar FI, Abadi E, Sotoudeh-Paima S, Fricks RB, Mazurowski MA, Segars WP, et al. Virtual vs. reality: External validation of COVID-19 classifiers using XCAT phantoms for chest computed tomography. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2022.
- Tushar FI, Nujaim H, Fu W, Abadi E, Mazurowski MA, Segars WP, et al. Quality or quantity: toward a unified approach for multi-organ segmentation in body CT. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2022.
- McCabe C, Zarei M, Segars WP, Samei E, Abadi E. Optimization of imaging parameters of an investigational photon-counting CT prototype for lung lesion radiomics. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2022.
- Pijanowski J, Pretorius PH, Lindsay C, Segars WP, Ljungberg M, Dugan M, et al. Development of a Population of Digital Anthropomorphic Phantoms with Simulated Acquisitions for use in Deep Learning Improvement of DMSA Quantification and Estimation of Attenuation Maps from Emission Reconstructions in DMSA Pediatric SPECT Imaging. In: 2022 IEEE NSS Mic Rtsd IEEE Nuclear Science Symposium Medical Imaging Conference and Room Temperature Semiconductor Detector Conference. 2022.
- Fricks RB, Ria F, Chalian H, Khoshpouri P, Abadi E, Bianchi L, et al. Deep learning classification of COVID-19 in chest radiographs: performance and influence of supplemental training. J Med Imaging (Bellingham). 2021 Nov;8(6):064501.
- Ria F, Fu W, Hoye J, Segars WP, Kapadia AJ, Samei E. Correction to: Comparison of 12 surrogates to characterize CT radiation risk across a clinical population. Eur Radiol. 2021 Oct;31(10):8068.
- Jadick G, Abadi E, Harrawood B, Sharma S, Segars WP, Samei E. A scanner-specific framework for simulating CT images with tube current modulation. Phys Med Biol. 2021 Sep 13;66(18).
- Ria F, Fu W, Hoye J, Segars WP, Kapadia AJ, Samei E. Comparison of 12 surrogates to characterize CT radiation risk across a clinical population. Eur Radiol. 2021 Sep;31(9):7022u201330.
- Fu W, Sharma S, Abadi E, Iliopoulos A-S, Wang Q, Lo JY, et al. iPhantom: A Framework for Automated Creation of Individualized Computational Phantoms and Its Application to CT Organ Dosimetry. IEEE J Biomed Health Inform. 2021 Aug;25(8):3061u201372.
- Bauer DF, Russ T, Waldkirch BI, Tu00f6nnes C, Segars WP, Schad LR, et al. Generation of annotated multimodal ground truth datasets for abdominal medical image registration. Int J Comput Assist Radiol Surg. 2021 Aug;16(8):1277u201385.
- Divel SE, Christensen S, Segars WP, Lansberg MG, Pelc NJ. A dynamic simulation framework for CT perfusion in stroke assessment built from first principles. Med Phys. 2021 Jul;48(7):3500u201310.
- Gullberg GT, Shrestha UM, Veress AI, Segars WP, Liu J, Ordovas K, et al. Novel Methodology for Measuring Regional Myocardial Efficiency. IEEE Trans Med Imaging. 2021 Jun;40(6):1711u201325.
- Chang Y, Jiang Z, Segars WP, Zhang Z, Lafata K, Cai J, et al. A generative adversarial network (GAN)-based technique for synthesizing realistic respiratory motion in the extended cardiac-torso (XCAT) phantoms. Phys Med Biol. 2021 May 31;66(11).
- Tanaka R, Samei E, Segars WP, Abadi E, Matsumoto I, Tamura M, et al. Assessment of pleural invasion and adhesion of lung tumors with dynamic chest radiography: A virtual clinical imaging study. Med Phys. 2021 Apr;48(4):1616u201323.
- Sharma S, Abadi E, Kapadia A, Segars WP, Samei E. A GPU-accelerated framework for rapid estimation of scanner-specific scatter in CT for virtual imaging trials. Phys Med Biol. 2021 Mar 23;66(7).
- Fu W, Ria F, Segars WP, Choudhury KR, Wilson JM, Kapadia AJ, et al. Patient-Informed Organ Dose Estimation in Clinical CT: Implementation and Effective Dose Assessment in 1048 Clinical Patients. AJR Am J Roentgenol. 2021 Mar;216(3):824u201334.
- Abadi E, Paul Segars W, Chalian H, Samei E. Virtual Imaging Trials for Coronavirus Disease (COVID-19). AJR Am J Roentgenol. 2021 Feb;216(2):362u20138.
- Zarei M, Abadi E, Fricks R, Segars WP, Samei E. A probabilistic conditional adversarial neural network to reduce imaging variation in radiography. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2021.
- Zarei M, Abadi E, Segars WP, Richards T, Samei E. Multi-factorial optimization of imaging parameters for quantifying coronary stenosis in cardiac ct. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2021.
- Fu W, Segars PW, Sharma S, Lo JY, Samei E. IPhantom: An automated framework in generating personalized computational phantoms for organ-based radiation dosimetry. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2021.
- Samei E, Richards T, Segars WP, Daubert MA, Ivanov A, Rubin GD, et al. Task-dependent estimability index to assess the quality of cardiac computed tomography angiography for quantifying coronary stenosis. J Med Imaging (Bellingham). 2021 Jan;8(1):013501.
- Abadi E, Jadick G, Hoffman EA, Lynch D, Segars WP, Samei E. Copd quantifications via ct imaging: Ascertaining the effects of acquisition protocol using virtual imaging trial. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2021.
- Ishihara N, Tanaka R, Segars WP, Abadi E, Samei E. Estimation of lung volume changes from frontal and lateral views of dynamic chest radiography using a convolutional neural network model: A computational phantom study. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2021.
- Sauer TJ, Abadi E, Segars WP, Samei E. Optimization of CT angiography using physiologically-informed computational plaques, dynamic XCAT phantoms, and physics-based CT simulation. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2021.
- Jadick G, Abadi E, Harrawood B, Sharma S, Segars WP, Samei E. A framework to simulate ct images with tube current modulation. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2021.
- Sugiura T, Tanaka R, Segars WP, Abadi E, Samei E. Correlation of respiratory changes in lung density on dynamic chest radiographs with changes in the ct value: A computational phantom study. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2021.
- Gann AM, Abadi E, Hoye J, Sauer TJ, Segars WP, Chalian H, et al. An analysis of radiomics features in lung lesions in covid-19. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2021.
- Abadi E, Segars W, Sharma S, Ria F, Chalian H, Samei E. Virtual Imaging Trials for Novel Coronavirus Disease (COVID-19). In 2020.
- Ria F, Fu W, Chalian H, Segars W, Fricks R, Khoshpouri P, et al. Justification of radiological procedures in COVID-19 pandemic based on radiation risk only. In 2020.
- Taguchi K, Sauer TJ, Segars WP, Frey EC, Xu J, Liapi E, et al. Three-dimensional regions-of-interest-based intra-operative four-dimensional soft tissue perfusion imaging using a standard x-ray system with no gantry rotation: A simulation study for a proof of concept. Med Phys. 2020 Dec;47(12):6087u2013102.
- MacDonald LR, Lo JY, Sturgeon GM, Zeng C, Harrison RL, Kinahan PE, et al. Impact of Using Uniform Attenuation Coefficients for Heterogeneously Dense Breasts in a Dedicated Breast PET/X-ray Scanner. IEEE Trans Radiat Plasma Med Sci. 2020 Sep;4(5):585u201393.
- Abadi E, Segars WP, Harrawood B, Sharma S, Kapadia A, Samei E. Virtual clinical trial for quantifying the effects of beam collimation and pitch on image quality in computed tomography. J Med Imaging (Bellingham). 2020 Jul;7(4):042806.
- Abadi E, Segars WP, Tsui BMW, Kinahan PE, Bottenus N, Frangi AF, et al. Virtual clinical trials in medical imaging: a review. J Med Imaging (Bellingham). 2020 Jul;7(4):042805.
- Ria F, Fu W, Hoye J, Segars W, Kapadia A, Samei E. Clinical Decision Making in CT: Risk Assessment Comparison Across 12 Risk Metrics in Patient Populations. In: Journal of Medical Physics. Medknow Publications; 2020. p. e519u2013e519.
- THE 2020 AAPM ANNUAL MEETING PROGRAM. In: Med Phys. 2020. p. e255-2720.
- Chang Y, Lafata K, Segars WP, Yin F-F, Ren L. Development of realistic multi-contrast textured XCAT (MT-XCAT) phantoms using a dual-discriminator conditional-generative adversarial network (D-CGAN). Phys Med Biol. 2020 Mar 19;65(6):065009.
- Samei E, Abadi E, Kapadia A, Lo J, Mazurowski M, Segars P. Virtual imaging trials: An emerging experimental paradigm in imaging research and practice. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2020.
- Gullberg G, Shrestha U, Veress A, Segars WP, Liu J, Ordovas K, et al. NOVEL METHODOLGY FOR MEASURING REGIONAL MYOCARDIAL EFFICIENCY. In: JOURNAL OF NUCLEAR MEDICINE. 2020.
- Abadi E, Rajagopal J, Sauer T, Jones E, Segars WP, Samei E. Optimization of energy thresholds in photon-counting CT via a virtual clinical trial. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2020.
- Tanaka R, Samei E, Segars WP, Abadi E, Matsumoto I, Tamura M, et al. Prediction of pleural invasion of lung cancer with dynamic chest radiography: A simulation study. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2020.
- Sharma S, Kapadia A, Fu W, Abadi E, Segars WP, Samei E. A real-time Monte Carlo tool for individualized dose estimations in clinical CT. Phys Med Biol. 2019 Nov 4;64(21):215020.
- Hoye J, Sharma S, Zhang Y, Fu W, Ria F, Kapadia A, et al. Organ doses from CT localizer radiographs: Development, validation, and application of a Monte Carlo estimation technique. Med Phys. 2019 Nov;46(11):5262u201372.
- Hoye J, Sharma S, Zhang Y, Fu W, Ria F, Kapadia A, et al. Organ doses from CT localizer radiographs: Development, validation, and application of a Monte Carlo estimation technique. MEDICAL PHYSICS. 2019 Nov 1;46(11):5262u201372.
- Abadi E, Harrawood B, Rajagopal JR, Sharma S, Kapadia A, Segars WP, et al. Development of a scanner-specific simulation framework for photon-counting computed tomography. Biomed Phys Eng Express. 2019 Aug;5(5).
- Gullberg GT, Veress AI, Shrestha UM, Liu J, Ordovas K, Segars WP, et al. Multiresolution spatiotemporal mechanical model of the heart as a prior to constrain the solution for 4D models of the heart. Proc SPIE Int Soc Opt Eng. 2019 Jun;11072.
- Abadi E, Harrawood B, Sharma S, Kapadia A, Segars WP, Samei E. DukeSim: A Realistic, Rapid, and Scanner-Specific Simulation Framework in Computed Tomography. IEEE Trans Med Imaging. 2019 Jun;38(6):1457u201365.
- Roy CW, Marini D, Segars WP, Seed M, Macgowan CK. Fetal XCMR: a numerical phantom for fetal cardiovascular magnetic resonance imaging. J Cardiovasc Magn Reson. 2019 May 23;21(1):29.
- Veress A, Shrestha U, Liu J, Ordovas K, Gullberg G, Segars WP, et al. IN VIVO MEASURE OF CARDIAC EFFICIENCY USING HYBRID PET/MRI TECHNOLOGY. In: JOURNAL OF NUCLEAR MEDICINE. SOC NUCLEAR MEDICINE INC; 2019.
- Sharma S, Abadi E, Kapadia A, Segars WP, Samei E. A comprehensive GPU-based framework for scatter estimation in single source, dual source, and photon-counting CT. In: Medical Imaging 2019: Physics of Medical Imaging. 2019. p. 109482V-109482V.
- Sauer TJ, Abadi E, Segars P, Samei E. Anatomically- and computationally-informed hepatic contrast perfusion simulations for use in virtual clinical trials. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2019.
- Tanaka R, Samei E, Segars P, Abadi E, Roth H, Oda H, et al. Dynamic chest radiography for pulmonary function diagnosis: A validation study using 4D extended cardiac-torso (XCAT) phantom. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2019.
- Segars WP, Veress AI, Sturgeon GM, Samei E. Incorporation of the Living Heart Model into the 4D XCAT Phantom for Cardiac Imaging Research. IEEE Trans Radiat Plasma Med Sci. 2019 Jan;3(1):54u201360.
- Abadi E, Segars WP, Sturgeon GM, Harrawood B, Kapadia A, Samei E. Modeling "Textured" Bones in Virtual Human Phantoms. IEEE Trans Radiat Plasma Med Sci. 2019 Jan;3(1):47u201353.
- Abadi E, Harrawood B, Rajagopal J, Sharma S, Kapadia A, Sedlmair M, et al. A framework for realistic virtual clinical trials in photon counting computed tomography. In: Medical Imaging 2019: Physics of Medical Imaging. 2019. p. 109484F-109484F.
- Fu W, Sharma S, Smith T, Hou R, Abadi E, Selvakumaran V, et al. Multi-organ segmentation in clinical-computed tomography for patient-specific image quality and dose metrology. In: Medical Imaging 2019: Physics of Medical Imaging. 2019. p. 1094829u20131094829.
- Veress AI, Segars WP, Samei E. Utilizing deformable image registration to create new living human heart models for imaging simulation. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2019.
- Liu Y, Fu W, Selvakumaran V, Phelan M, Segars WP, Samei E, et al. Deep learning of 3D computed tomography (CT) images for organ segmentation using 2D multi-channel SegNet model. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2019.
- Richards T, Ivanov A, Segars P, Hoffmann U, Samei E. Cardiac CT estimability index: An ideal estimator in the presence of noise and motion. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2019.
- Abadi E, Segars WP, Harrawood B, Sharma S, Sauer T, Kapadia A, et al. Trade-off between spatial details and motion artifact in multi-detector CT: A virtual clinical trial with 4D textured human models. In: Medical Imaging 2019: Physics of Medical Imaging. 2019. p. 109482R-109482R.
- Fu W, Ria F, Wilson J, Kapadia AJ, Segars WP, Samei E. Effective Dose for Computed Tomography in Large, Clinical Populations. In 2018.
- Ria F, Fu W, Zhang Y, Hoye J, Segars WP, Kapadia AJ, et al. Characterization of Radiation Risk across a Clinical CT Patient Population: Comparison across 12 Risks Metrics. In 2018.
- Segars WP, Tsui BMW, Jing Cai, Fang-Fang Yin, Fung GSK, Samei E. Application of the 4-D XCAT Phantoms in Biomedical Imaging and Beyond. IEEE Trans Med Imaging. 2018 Mar;37(3):680u201392.
- Abadi E, Segars WP, Sturgeon GM, Roos JE, Ravin CE, Samei E. Modeling Lung Architecture in the XCAT Series of Phantoms: Physiologically Based Airways, Arteries and Veins. IEEE Trans Med Imaging. 2018 Mar;37(3):693u2013702.
- Richards T, Sturgeon GM, Ramirez-Giraldo JC, Rubin GD, Koweek LH, Segars WP, et al. Quantification of uncertainty in the assessment of coronary plaque in CCTA through a dynamic cardiac phantom and 3D-printed plaque model. J Med Imaging (Bellingham). 2018 Jan;5(1):013501.
- Sharma S, Kapadia A, Abadi E, Fu W, Segars WP, Samei E. A rapid GPU-based Monte-Carlo simulation tool for individualized dose estimations in CT. In: Medical Imaging 2018: Physics of Medical Imaging. 2018. p. 105733V-105733V.
- Abadi E, Segars WP, Harrawood B, Kapadia A, Samei E. Virtual clinical trial in action: Textured XCAT phantoms and scanner-specific CT simulator to characterize noise across CT reconstruction algorithms. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2018.
- Fu W, Segars WP, Abadi E, Sharma S, Kapadia AJ, Samei E. From patient-informed to patient-specific organ dose estimation in clinical computed tomography. In: Medical Imaging 2018: Physics of Medical Imaging. 2018. p. 1057315u20131057315.
- Abadi E, Harrawood B, Kapadia A, Segars WP, Samei E. Development of a fast, voxel-based, and scanner-specific CT simulator for image-quality-based virtual clinical trials. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2018.
- Rajagopal J, Sturgeon GM, Chen XC, Sauer TJ, Ren Y, Segars WP, et al. Evaluation of statistical breast phantoms with higher resolution. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2018.
- Richards T, Segars P, Samei E. Variability of stenosis characterization: Impact of coronary vessel motion in cardiac CT. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2018.
- Samei E, Tian X, Paul Segars W, Frush DP. Radiation risk index for pediatric CT: a patient-derived metric. Pediatr Radiol. 2017 Dec;47(13):1737u201344.
- Wang C, Yin F-F, Segars WP, Chang Z, Ren L. Development of a Computerized 4-D MRI Phantom for Liver Motion Study. Technol Cancer Res Treat. 2017 Dec;16(6):1051u20139.
- Sturgeon GM, Park S, Segars WP, Lo JY. Synthetic breast phantoms from patient based eigenbreasts. Med Phys. 2017 Dec;44(12):6270u20139.
- Hoye J, Zhang Y, Agasthya G, Sturgeon G, Kapadia A, Segars WP, et al. Organ dose variability and trends in tomosynthesis and radiography. J Med Imaging (Bellingham). 2017 Jul;4(3):031207.
- Fu W, Sturgeon GM, Agasthya G, Segars WP, Kapadia AJ, Samei E. Breast dose reduction with organ-based, wide-angle tube current modulated CT. J Med Imaging (Bellingham). 2017 Jul;4(3):031208.
- Tang J, Wang X, Gao X, Segars WP, Lodge MA, Rahmim A. Enhancing ejection fraction measurement through 4D respiratory motion compensation in cardiac PET imaging. Phys Med Biol. 2017 Jun 7;62(11):4496u2013513.
- Sahbaee P, Abadi E, Segars WP, Marin D, Nelson RC, Samei E. The Effect of Contrast Material on Radiation Dose at CT: Part II. A Systematic Evaluation across 58 Patient Models. Radiology. 2017 Jun;283(3):749u201357.
- Sahbaee P, Segars WP, Marin D, Nelson RC, Samei E. The Effect of Contrast Material on Radiation Dose at CT: Part I. Incorporation of Contrast Material Dynamics in Anthropomorphic Phantoms. Radiology. 2017 Jun;283(3):739u201348.
- Carver DE, Kost SD, Fraser ND, Segars WP, Pickens DR, Price RR, et al. Realistic phantoms to characterize dosimetry in pediatric CT. Pediatr Radiol. 2017 May;47(6):691u2013700.
- Muryn JS, Morgan AG, Liptak CL, Dong FF, Segars WP, Primak AN, et al. Analysis of uncertainties in Monte Carlo simulated organ and effective dose in chest CT: scanner- and scan-related factors. Phys Med Biol. 2017 Apr 21;62(8):3175u2013203.
- Dasari PKR, Ku00f6nik A, Pretorius PH, Johnson KL, Segars WP, Shazeeb MS, et al. Correction of hysteretic respiratory motion in SPECT myocardial perfusion imaging: Simulation and patient studies. Med Phys. 2017 Feb;44(2):437u201350.
- Fu W, Tian X, Sturgeon GM, Agasthya G, Segars WP, Goodsitt MM, et al. CT breast dose reduction with the use of breast positioning and organ-based tube current modulation. Med Phys. 2017 Feb;44(2):665u201378.
- Fu W, Sturgeon GM, Agasthya G, Segars WP, Kapadia AJ, Samei E. Estimation of breast dose reduction potential for organ-based tube current modulated CT with wide dose reduction arc. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2017.
- Hoye J, Zhang Y, Agasthya G, Sturgeon G, Kapadia A, Segars WP, et al. An atlas-based organ dose estimator for tomosynthesis and radiography. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2017.
- Sturgeon GM, Richards TW, Samei E, Segars WP. Improved virtual cardiac phantom with variable diastolic filling rates and coronary artery velocities. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2017.
- Sanders J, Tian X, Segars WP, Boone J, Samei E. Automated, patient-specific estimation of regional imparted energy and dose from tube current modulated computed tomography exams across 13 protocols. J Med Imaging (Bellingham). 2017 Jan;4(1):013503.
- Abadi E, Sturgeon GM, Agasthya G, Harrawood B, Hoeschen C, Kapadia A, et al. Airways, vasculature, and interstitial tissue: Anatomically informed computational modeling of human lungs for virtual clinical trials. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2017.
- Sauer TJ, Graff CG, Zeng R, Santana M, Sturgeon GM, Bosmans H, et al. Detectability of artificial lesions in anthropomorphic virtual breast phantoms of variable glandular fraction. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2017.
- Kiarashi N, Nolte LW, Lo JY, Segars WP, Ghate SV, Solomon JB, et al. Impact of breast structure on lesion detection in breast tomosynthesis, a simulation study. J Med Imaging (Bellingham). 2016 Jul;3(3):035504.
- Tian X, Segars WP, Dixon RL, Samei E. Convolution-based estimation of organ dose in tube current modulated CT. Phys Med Biol. 2016 May 21;61(10):3935u201354.
- Sturgeon GM, Kiarashi N, Lo JY, Samei E, Segars WP. Finite-element modeling of compression and gravity on a population of breast phantoms for multimodality imaging simulation. Med Phys. 2016 May;43(5):2207.
- Krishnamurthy A, Gonzales MJ, Sturgeon G, Segars WP, McCulloch AD. Biomechanics Simulations Using Cubic Hermite Meshes with Extraordinary Nodes for Isogeometric Cardiac Modeling. Comput Aided Geom Des. 2016 Mar;43:27u201338.
- Smyczynski MS, Gifford HC, Lehovich A, McNamara JE, Segars WP, Hoffman EA, et al. Modeling the respiratory motion of solitary pulmonary nodules and determining the impact of respiratory motion on their detection in SPECT imaging. IEEE Trans Nucl Sci. 2016 Feb;63(1):117u201329.
- Smyczynski MS, Gifford HC, Dey J, Lehovich A, McNamara JE, Segars WP, et al. LROC Investigation of Three Strategies for Reducing the Impact of Respiratory Motion on the Detection of Solitary Pulmonary Nodules in SPECT. IEEE Trans Nucl Sci. 2016 Feb;63(1):130u20139.
- Divel SE, Segars WP, Christensen S, Wintermark M, Lansberg MG, Pelc NJ. Development of a realistic, dynamic digital brain phantom for CT perfusion validation. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2016.
- Becchetti MF, Solomon JB, Segars WP, Samei E. Synthesized interstitial lung texture for use in anthropomorphic computational phantoms. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2016.
- Sturgeon GM, Tward DJ, Ketcha M, Ratnanather JT, Miller MI, Park S, et al. Eigenbreasts for statistical breast phantoms. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2016.
- Fu W, Tian X, Sahbaee P, Zhang Y, Segars WP, Samei E. Organ dose conversion coefficients for tube current modulated CT protocols for an adult population. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2016.
- Sanders JW, Tian X, Segars WP, Boone J, Samei E. An automated technique for estimating patient-specific regional imparted energy and dose in TCM CT exams. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2016.
- Fu W, Tian X, Sturgeon G, Agasthya G, Segars WP, Goodsitt MM, et al. Estimation of breast dose saving potential using a breast positioning technique for organ-based tube current modulated CT. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2016.
- Erickson DW, Wells JR, Sturgeon GM, Samei E, Dobbins JT, Segars WP, et al. Population of 224 realistic human subject-based computational breast phantoms. Med Phys. 2016 Jan;43(1):23.
- Li X, Morgan AG, Liptak CL, Muryn JS, Dong FF, Primak AN, et al. Adult abdomen-pelvis CT: Does equilibrium dose-pitch product better account for the kVp dependence of organ dose than conventional CTDI? Med Phys. 2015 Nov;42(11):6258u201368.
- Stabin MG, Kost SD, Segars WP, Guilmette RA. Two Realistic Beagle Models for Dose Assessment. Health Phys. 2015 Sep;109(3):198u2013204.
- Segars WP, Norris H, Sturgeon GM, Zhang Y, Bond J, Minhas A, et al. The development of a population of 4D pediatric XCAT phantoms for imaging research and optimization. Med Phys. 2015 Aug;42(8):4719u201326.
- Dey J, Segars WP, Pretorius PH, King MA. Effect of Non-Alignment/Alignment of Attenuation Map Without/With Emission Motion Correction in Cardiac SPECT/CT. IEEE Trans Nucl Sci. 2015 Aug;62(4):1813u201324.
- Sung Y, Segars WP, Pan A, Ando M, Sheppard CJR, Gupta R. Realistic wave-optics simulation of X-ray phase-contrast imaging at a human scale. Sci Rep. 2015 Jul 14;5:12011.
- Kiarashi N, Nolte AC, Sturgeon GM, Segars WP, Ghate SV, Nolte LW, et al. Development of realistic physical breast phantoms matched to virtual breast phantoms based on human subject data. Med Phys. 2015 Jul;42(7):4116u201326.
- Veress AI, Fung GSK, Lee T-S, Tsui BMW, Kicska GA, Paul Segars W, et al. The direct incorporation of perfusion defect information to define ischemia and infarction in a finite element model of the left ventricle. J Biomech Eng. 2015 May;137(5):051004.
- Tian X, Li X, Segars WP, Frush DP, Samei E. Prospective estimation of organ dose in CT under tube current modulation. Med Phys. 2015 Apr;42(4):1575u201385.
- Elangovan P, Rashidnasab A, Mackenzie A, Dance DR, Young KC, Bosmans H, et al. Performance comparison of breast imaging modalities using a 4AFC human observer study. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2015.
- Liptak CL, Tovey D, Segars WP, Dong FD, Li X. Anatomy-based transmission factors for technique optimization in portable chest x-ray. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2015.
- Muryn JS, Morgan AG, Segars WP, Liptak CL, Dong FF, Primak AN, et al. Analysis of uncertainties in Monte Carlo simulated organ dose for chest CT. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2015.
- Tian X, Segars WP, Dixon RL, Samei E. Convolution-based estimation of organ dose in tube current modulated CT. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2015.
- Kiarashi N, Nolte LW, Lo JY, Segars WP, Ghate SV, Samei E. The impact of breast structure on lesion detection in breast tomosynthesis. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2015.
- Sahbaee P, Li Y, Segars P, Marin D, Nelson R, Samei E. Determination of contrast media administration to achieve a targeted contrast enhancement in CT. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2015.
- Tremblay M, Kramer GH, Capello K, Segars P. Effect of respiratory motion on lung counting efficiency using a 4D NURBS-based cardio-torso (NCAT) phantom. Health Phys. 2014 Dec;107(6):564u20139.
- Segars WP, Rybicki K, Norris H, Frush D, Samei E. Organ localization: toward prospective patient-specific organ dosimetry in computed tomography. Med Phys. 2014 Dec;41(12):121908.
- Samei E, Tian X, Segars WP. Determining organ dose: the holy grail. Pediatr Radiol. 2014 Oct;44 Suppl 3:460u20137.
- Sechopoulos I, Sabol JM, Berglund J, Bolch WE, Brateman L, Christodoulou E, et al. Radiation dosimetry in digital breast tomosynthesis: report of AAPM Tomosynthesis Subcommittee Task Group 223. Med Phys. 2014 Sep;41(9):091501.
- Li X, Segars WP, Samei E. The impact on CT dose of the variability in tube current modulation technology: a theoretical investigation. Phys Med Biol. 2014 Aug 21;59(16):4525u201348.
- Wissmann L, Santelli C, Segars WP, Kozerke S. MRXCAT: Realistic numerical phantoms for cardiovascular magnetic resonance. J Cardiovasc Magn Reson. 2014 Aug 20;16(1):63.
- Ku00f6nik A, Connolly CM, Johnson KL, Dasari P, Segars PW, Pretorius PH, et al. Digital anthropomorphic phantoms of non-rigid human respiratory and voluntary body motion for investigating motion correction in emission imaging. Phys Med Biol. 2014 Jul 21;59(14):3669u201382.
- Sahbaee P, Segars WP, Samei E. Patient-based estimation of organ dose for a population of 58 adult patients across 13 protocol categories. Med Phys. 2014 Jul;41(7):072104.
- Kiarashi N, Lo JY, Lin Y, Ikejimba LC, Ghate SV, Nolte LW, et al. Development and application of a suite of 4-D virtual breast phantoms for optimization and evaluation of breast imaging systems. IEEE Trans Med Imaging. 2014 Jul;33(7):1401u20139.
- Belley MD, Segars WP, Kapadia AJ. Assessment of individual organ doses in a realistic human phantom from neutron and gamma stimulated spectroscopy of the breast and liver. Med Phys. 2014 Jun;41(6):063902.
- Norris H, Zhang Y, Bond J, Sturgeon GM, Minhas A, Tward DJ, et al. A set of 4D pediatric XCAT reference phantoms for multimodality research. Med Phys. 2014 Mar;41(3):033701.
- Tian X, Li X, Segars WP, Paulson EK, Frush DP, Samei E. Pediatric chest and abdominopelvic CT: organ dose estimation based on 42 patient models. Radiology. 2014 Feb;270(2):535u201347.
- Zhang Y, Li X, Segars WP, Samei E. Comparison of patient specific dose metrics between chest radiography, tomosynthesis, and CT for adult patients of wide ranging body habitus. Med Phys. 2014 Feb;41(2):023901.
- Segars WP, Veress AI, Wells JR, Sturgeon GM, Kiarashi N, Lo JY, et al. Population of 100 realistic, patient-based computerized breast phantoms for multi-modality imaging research. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2014.
- Veress AI, Coleman BR, Farrar G, Segars WP, Fabien BC. Image-based estimation of passive myocardial properties using finite element modeling. In: Handbook of Imaging in Biological Mechanics. 2014. p. 155u201371.
- Nolte A, Kiarashi N, Samei E, Segars WP, Lo JY. A second generation of physical anthropomorphic 3D breast phantoms based on human subject data. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2014.
- Norris H, Zhang Y, Frush J, Sturgeon GM, Minhas A, Tward DJ, et al. The development of a population of 4D pediatric XCAT phantoms for CT imaging research and optimization. Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2014 Jan 1;9033.
- Tian X, Li X, Segars WP, Frush D, Samei E. Prospective optimization of CT under Tube current modulation: I. organ dose. Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2014 Jan 1;9033.
- Dobbins JT, Wells JR, Segars WP. Dose reduction in CT with correlated-polarity noise reduction: Context-dependent spatial resolution and noise properties demonstrating two-fold dose reduction with minimal artifacts. Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2014 Jan 1;9033.
- Tian X, Li X, Segars WP, Frush DP, Paulson EK, Samei E. Dose coefficients in pediatric and adult abdominopelvic CT based on 100 patient models. Phys Med Biol. 2013 Dec 21;58(24):8755u201368.
- Zhang Y, Yin F-F, Segars WP, Ren L. A technique for estimating 4D-CBCT using prior knowledge and limited-angle projections. Med Phys. 2013 Dec;40(12):121701.
- Vergalasova I, Cai J, Giles W, Segars WP, Yin FF. Evaluation of the effect of respiratory and anatomical variables on a Fourier technique for markerless, self-sorted 4D-CBCT. Phys Med Biol. 2013 Oct 21;58(20):7239u201359.
- Gonzales MJ, Sturgeon G, Krishnamurthy A, Hake J, Jonas R, Stark P, et al. A three-dimensional finite element model of human atrial anatomy: new methods for cubic Hermite meshes with extraordinary vertices. Med Image Anal. 2013 Jul;17(5):525u201337.
- Cheng L, Hobbs RF, Segars PW, Sgouros G, Frey EC. Improved dose-volume histogram estimates for radiopharmaceutical therapy by optimizing quantitative SPECT reconstruction parameters. Phys Med Biol. 2013 Jun 7;58(11):3631u201347.
- Bond J, Frush D, Samei E, Segars WP. Simulation of anatomical texture in voxelized XCAT phantoms. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2013.
- Zhang Y, Li X, Paul Segars W, Samei E. Comparative dosimetry of radiography, tomosynthesis, and CT for chest imaging across 59 adult patients. Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2013 Jun 3;8668.
- Li X, Segars WP, Samei E. Organ dose in chest CT: Effect of modulation scheme on estimation accuracy. Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2013 Jun 3;8668.
- Segars WP, Bond J, Frush J, Hon S, Eckersley C, Williams CH, et al. Population of anatomically variable 4D XCAT adult phantoms for imaging research and optimization. Med Phys. 2013 Apr;40(4):043701.
- Hsu CML, Palmeri ML, Segars WP, Veress AI, Dobbins JT. Generation of a suite of 3D computer-generated breast phantoms from a limited set of human subject data. Med Phys. 2013 Apr;40(4):043703.
- III JTD, Wells JR, Segars WP. Dose reduction in CT with correlated-polarity noise reduction: Comparable image quality at half the dose with projection space processing. Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2013;8668.
- Genc K, Segars P, Cockram S, Thompson D, Horner M, Cotton R, et al. Workflow for creating a simulation ready virtual population for finite element modeling. ASME 2013 Conference on Frontiers in Medical Devices Applications of Computer Modeling and Simulation Fmd 2013. 2013 Jan 1;
- Kiarashi N, Sturgeon GM, Nolte LW, Lo JY, III JTD, Segars WP, et al. Development of matched virtual and physical breast phantoms based on patient data. In: Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2013.
- Zubal IG, Segars WP. Anthropomorphic Phantoms: Early Developments and Current Advances. In: MONTE CARLO CALCULATIONS IN NUCLEAR MEDICINE, 2ND EDITION: APPLICATIONS IN DIAGNOSTIC IMAGING. 2013. p. 31u201344.
- Wilson JM, Chisholm KL, Oldan JD, Segars WP, Turkington TG, Chin BB. Patient-specific model of NaF PET to facilitate multicenter clinical trial PET imaging protocols and analysis: preliminary results of a CT-based simulation. In: JOURNAL OF NUCLEAR MEDICINE. 2013. p. 26u20137.
- Dey J, Konik A, Segars WP, King MA. Multi-modal rigid and non-rigid registration for attenuation correction in cardiac SPECT/CT using emission scatter to CT conversion. IEEE Nuclear Science Symposium Conference Record. 2012 Dec 1;2859u201366.
- Li X, Samei E, Williams CH, Segars WP, Tward DJ, Miller MI, et al. Effects of protocol and obesity on dose conversion factors in adult body CT. Med Phys. 2012 Nov;39(11):6550u201371.
- Stabin MG, Xu XG, Emmons MA, Segars WP, Shi C, Fernald MJ. RADAR reference adult, pediatric, and pregnant female phantom series for internal and external dosimetry. J Nucl Med. 2012 Nov;53(11):1807u201313.
- Mishra P, St James S, Segars WP, Berbeco RI, Lewis JH. Adaptation and applications of a realistic digital phantom based on patient lung tumor trajectories. Phys Med Biol. 2012 Jun 7;57(11):3597u2013608.
- Qin Y, Chang Z, Segars W, Yin F, Cai J. SU-D-218-02: 4D-MRI Based on Body Area (BA) Surrogate and Sagittal Image Acquisition. Med Phys. 2012 Jun;39(6Part3):3622.
- Zhang F, Qin Y, Segars W, Yin F, Cai J. MO-A-213AB-04: Verification of 4D Dose Delivery Using 4D Digital Human Phantom. Med Phys. 2012 Jun;39(6Part20):3859.
- Zhang Y, Li X, Segars WP, Samei E. Organ doses, effective doses, and risk indices in adult CT: comparison of four types of reference phantoms across different examination protocols. Med Phys. 2012 Jun;39(6):3404u201323.
- Panta R, Segars W, Yin F, Cai J. SU-E-J-145: Implementing 4D XCAT Phantom for 4D Radiotherapy Research. Med Phys. 2012 Jun;39(6Part8):3686.
- Lindsay C, Gennert MA, Connolly CM, Konik A, Dasari PK, Segars WP, et al. Interactive generation of digital anthropomorphic phantoms from XCAT shape priors. Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2012 May 14;8317.
- Bond J, Frush J, Hon S, Eckersley C, Williams CH, Feng J, et al. Series of 4D adult XCAT phantoms for imaging research and dosimetry. Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2012 May 4;8313.
- Tian X, Li X, Segars WP, Frush DP, Samei E. Patient- and cohort-specific dose and risk estimation for abdominopelvic CT: A study based on 100 patients. Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2012 May 4;8313.
- Kiarashi N, Lin Y, Segars WP, Ghate SV, Ikejimba L, Chen B, et al. Development of a dynamic 4D anthropomorphic breast phantom for contrast-based breast imaging. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2012.
- Stabin MG, Emmons MA, Segars WP, Fernald MJ. Realistic reference adult and paediatric phantom series for internal and external dosimetry. Radiat Prot Dosimetry. 2012 Mar;149(1):56u20139.
- Mishra P, James SS, Segars W, Berbeco R, Lewis J. TUu2010Cu2010213CDu201006: Patient Lung Tumor Trajectory Based Modifiedu2010XCAT and Its Applications. In: Medical Physics. 2012. p. 3903.
- Zubal IG, Segars WP. Anthropomorphic Phantoms: Early Developments and Current Advances. In: Monte Carlo Calculations in Nuclear Medicine Applications in Diagnostic Imaging. 2012. p. 31u201344.
- Panta RK, Segars P, Yin F-F, Cai J. Establishing a framework to implement 4D XCAT phantom for 4D radiotherapy research. J Cancer Res Ther. 2012;8(4):565u201370.
- Cai J, Chang Z, Wang Z, Paul Segars W, Yin F-F. Four-dimensional magnetic resonance imaging (4D-MRI) using image-based respiratory surrogate: a feasibility study. Med Phys. 2011 Dec;38(12):6384u201394.
- Veress AI, Fung GSK, Tsui BMW, Segars WP, Gullberg GT. Incorporation of perfusion information into a finite element model of the left ventricle. ASME 2011 Summer Bioengineering Conference Sbc 2011. 2011 Dec 1;(PARTS A AND B):151u20132.
- Fung GSK, Higuchi T, Park MJ, Segars WP, Tsui BMW. Development of a 4D Digital Phantom for Tracer Kinetic Modeling and Analysis of Dynamic Perfusion PET and SPECT Simulation Studies. IEEE Nucl Sci Symp Conf Rec (1997). 2011 Oct;2011:4192u20135.
- Hsu CML, Palmeri ML, Segars WP, Veress AI, Dobbins JT. An analysis of the mechanical parameters used for finite element compression of a high-resolution 3D breast phantom. Med Phys. 2011 Oct;38(10):5756u201370.
- Fung GSK, Segars WP, Gullberg GT, Tsui BMW. Development of a model of the coronary arterial tree for the 4D XCAT phantom. Phys Med Biol. 2011 Sep 7;56(17):5651u201363.
- Tward DJ, Ceritoglu C, Sturgeon G, Segars WP, Miller MI, Ratnanather JT. Generating patient-specific dosimetry phantoms with whole-body diffeomorphic image registration. 2011 IEEE 37th Annual Northeast Bioengineering Conference Nebec 2011. 2011 Jun 16;
- Li X, Samei E, Segars WP, Sturgeon GM, Colsher JG, Frush DP. Patient-specific radiation dose and cancer risk for pediatric chest CT. Radiology. 2011 Jun;259(3):862u201374.
- Tang J, Segars WP, Lee T-S, He X, Rahmim A, Tsui BMW. Quantitative study of cardiac motion estimation and abnormality classification in emission computed tomography. Med Eng Phys. 2011 Jun;33(5):563u201372.
- Connolly CM, Konik A, Dasari PKR, Segars P, Zheng S, Johnson KL, et al. Creation of 3D digital anthropomorphic phantoms which model actual patient non-rigid body motion as determined from MRI and position tracking studies of volunteers. Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2011 May 16;7964.
- Wells JR, Segars WP, Kigongo CJN, Dobbins JT. Refinement of motion correction strategies for lower-cost CT for under-resourced regions of the world. Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2011 May 13;7961.
- Fung GSK, Stierstorfer K, Segars WP, Taguchi K, Flohr TG, Tsui BMW. XCAT/DRASIM: A realistic CT/human-model simulation package. Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2011 May 13;7961.
- Li X, Samei E, Segars WP, Paulson EK, Frush DP. The feasibility of universal DLP-to-risk conversion coefficients for body CT protocols. Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2011 May 13;7961.
- Veress AI, Segars WP, Tsui BMW, Gullberg GT. Incorporation of a left ventricle finite element model defining infarction into the XCAT imaging phantom. IEEE Trans Med Imaging. 2011 Apr;30(4):915u201327.
- Tward DJ, Ceritoglu C, Kolasny A, Sturgeon GM, Segars WP, Miller MI, et al. Patient Specific Dosimetry Phantoms Using Multichannel LDDMM of the Whole Body. Int J Biomed Imaging. 2011;2011:481064.
- Li X, Samei E, Segars WP, Sturgeon GM, Colsher JG, Toncheva G, et al. Patient-specific radiation dose and cancer risk estimation in CT: part II. Application to patients. Med Phys. 2011 Jan;38(1):408u201319.
- Li X, Samei E, Segars WP, Sturgeon GM, Colsher JG, Toncheva G, et al. Patient-specific radiation dose and cancer risk estimation in CT: part I. development and validation of a Monte Carlo program. Med Phys. 2011 Jan;38(1):397u2013407.
- Karakatsanis NA, Lodge MA, Zhou Y, Mhlanga J, Chaudhry MA, Tahari AK, et al. Dynamic multi-bed FDG PET imaging: Feasibility and optimization. IEEE Nuclear Science Symposium Conference Record. 2011 Jan 1;3863u201370.
- Dey J, Segars WP, Pretorius PH, King MA. Investigation of respiratory motion correction with and without motion correction of attenuation map in cardiac SPECT/CT in presence of non-rigid motion, an NCAT study. IEEE Nuclear Science Symposium Conference Record. 2011 Jan 1;3237u201343.
- Ku00f6nik A, Connolly CM, Johnson KL, Dasari P, Segars P, Pretorius PH, et al. Digital anthropomorphic phantoms of non-rigid human respiratory and voluntary body motions: A tool-set for investigating motion correction in 3D reconstruction. IEEE Nuclear Science Symposium Conference Record. 2011 Jan 1;3572u20138.
- Zhang Y, li X, Segars W, Samei E. THu2010Au2010214u201002: Organ Dose, Effective Dose, and Dose Conversion Coefficients in Adult CT: Comparison of Mathematical, XCAT, and ICRP Reference Phantoms. In: Medical Physics. 2011. p. 3842u20133.
- Dobbins JT, Wells JR, Segars WP, Li CM, Kigongo CJN. Initial investigation into lower-cost CT for resource limited regions of the world. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2010.
- Li X, Samei E, Segars WP, Sturgeon GM, Colsher JG, Frush DP. Patient-specific radiation dose and cancer risk estimation in pediatric chest CT: A study in 30 patients. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2010.
- Dey J, Segars WP, Pretorius PH, Walvick RP, Bruyant PP, Dahlberg S, et al. Estimation and correction of cardiac respiratory motion in SPECT in the presence of limited-angle effects due to irregular respiration. Med Phys. 2010 Dec;37(12):6453u201365.
- Segars WP, Sturgeon GM, Ward DJ, Ratnanather JT, Miller MI, Tsui BMW. The new XCAT series of digital phantoms for multi-modality imaging. IEEE Nuclear Science Symposium Conference Record. 2010 Dec 1;2392u20135.
- Cheung AA, Niu T, Faber TL, Segars WP, Zhu L, Chen J. Simulation of left ventricular dyssynchrony using the XCAT phantom. IEEE Nuclear Science Symposium Conference Record. 2010 Dec 1;3187u20139.
- Segars WP, Sturgeon G, Mendonca S, Grimes J, Tsui BMW. 4D XCAT phantom for multimodality imaging research. Med Phys. 2010 Sep;37(9):4902u201315.
- Tang J, Lee T-S, He X, Segars WP, Tsui BMW. Comparison of 3D OS-EM and 4D MAP-RBI-EM reconstruction algorithms for cardiac motion abnormality classification using a motion observer. IEEE Trans Nucl Sci. 2010 Aug 26;57(5):2571.
- Lewis JH, Li R, Watkins WT, Lawson JD, Segars WP, Cerviu00f1o LI, et al. Markerless lung tumor tracking and trajectory reconstruction using rotational cone-beam projections: a feasibility study. Phys Med Biol. 2010 May 7;55(9):2505u201322.
- McGurk R, Seco J, Riboldi M, Wolfgang J, Segars P, Paganetti H. Extension of the NCAT phantom for the investigation of intra-fraction respiratory motion in IMRT using 4D Monte Carlo. Phys Med Biol. 2010 Mar 7;55(5):1475u201390.
- Keenan MA, Stabin MG, Segars WP, Fernald MJ. RADAR realistic animal model series for dose assessment. J Nucl Med. 2010 Mar;51(3):471u20136.
- Fung GSK, Segars WP, Lee T-S, Higuchi T, Veress AI, Gullberg GT, et al. Realistic Simulation of Regional Myocardial Perfusion Defects for Cardiac SPECT Studies. IEEE Nucl Sci Symp Conf Rec (1997). 2010;2010:3061u20134.
- Xi H, Schafer BW, Segars WP, Eckstein F, Kuhn V, Beck TJ, et al. Assessing the Susceptibility to Local Buckling at the Femoral Neck Cortex to Age-Related Bone Loss. Ifmbe Proceedings. 2009 Dec 1;23:1918u20139.
- Tabary J, Marache-Francisco S, Valette S, Segars WP, Lartizien C. Realistic X-ray CT simulation of the XCAT phantom with SINDBAD. IEEE Nuclear Science Symposium Conference Record. 2009 Dec 1;3980u20133.
- Paul Segars W, Tsui BMW. MCAT to XCAT: The Evolution of 4-D Computerized Phantoms for Imaging Research: Computer models that take account of body movements promise to provide evaluation and improvement of medical imaging devices and technology. Proc IEEE Inst Electr Electron Eng. 2009 Dec;97(12):1954u201368.
- Minarik D, Ljungberg M, Segars P, Gleisner KS. Evaluation of quantitative planar 90Y bremsstrahlung whole-body imaging. Phys Med Biol. 2009 Oct 7;54(19):5873u201383.
- Segars WP, Lalush DS, Frey EC, Manocha D, King MA, Tsui BMW. Improved Dynamic Cardiac Phantom Based on 4D NURBS and Tagged MRI. IEEE Trans Nucl Sci. 2009 Oct 1;56(5):2728u201338.
- Lee T, Choi JB, Schafer BW, Segars WP, Eckstein F, Kuhn V, et al. Assessing the susceptibility to local buckling at the femoral neck cortex to age-related bone loss. Ann Biomed Eng. 2009 Sep;37(9):1910u201320.
- Li CM, Segars WP, Tourassi GD, Boone JM, Dobbins JT. Methodology for generating a 3D computerized breast phantom from empirical data. Med Phys. 2009 Jul;36(7):3122u201331.
- Fung GSK, Segars WP, Veress AI, Gullberg GT, Tsui BMW. Toward modeling of regional myocardial ischemia and infarction: Generation of realistic coronary arterial tree for the heart model of the XCAT phantom. Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2009 Jun 22;7262.
- Segars WP, Sturgeon G, Li X, Cheng L, Ceritoglu C, Ratnanather JT, et al. Patient specific computerized phantoms to estimate dose in pediatric CT. Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2009 Jun 16;7258.
- Li CM, Segars WP, Lo JY, Veress AI, Boone JM, Dobbins JT. Computerized 3D breast phantom with enhanced High-Resolution detail. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2009.
- Li X, Samei E, Segars WP, Sturgeon GM, Colsher JG, Frush DP. Patient-specific dose estimation for pediatric abdomen-pelvisCT. Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2009 Jun 15;7258.
- He B, Du Y, Segars WP, Wahl RL, Sgouros G, Jacene H, et al. Evaluation of quantitative imaging methods for organ activity and residence time estimation using a population of phantoms having realistic variations in anatomy and uptake. Med Phys. 2009 Feb;36(2):612u20139.
- Segars WP, Mok SP, Tsui BMW. Investigation of Respiratory Gating in Quantitative Myocardial SPECT. IEEE Trans Nucl Sci. 2009 Feb 1;56(1):91u20136.
- Stabin MG, Emmons-Keenan MA, Segars WP, Fernald MJ. The Vanderbilt University Reference Adult and Pediatric Phantom Series. In: Handbook of Anatomical Models for Radiation Dosimetry. 2009. p. 337u201346.
- Xu XG, Stabin MG, Bolch WE, Segars WP. Summary and Future Needs Related to Computational Phantoms. In: Handbook of Anatomical Models for Radiation Dosimetry. 2009. p. 679u201384.
- Smyczynski MS, Gifford HC, Lehovich A, McNamara JE, Segars WP, Dey J, et al. Effectiveness of three alternative strategies in reducing the degrading impact of respiratory motion on the detection of small pulmonary nodules in SPECT imaging. In: 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9. IEEE; 2009. p. 2938-+.
- Tsui BMW, Segars WP. Applications to Nuclear Medicine Imaging and Dosimetry Involving MCAT, NCAT, and MOBY Phantoms. In: Handbook of Anatomical Models for Radiation Dosimetry. 2009. p. 549u201366.
- Segars WP, Tsui BMW. The MCAT, NCAT, XCAT, and MOBY Computational Human and Mouse Phantoms. In: Handbook of Anatomical Models for Radiation Dosimetry. 2009. p. 105u201334.
- Dey J, Segars WP, Pretorius PH, King MA. Estimation and Correction of Irregular Respiratory motion of the Heart in Presence of Partial Angle Effects Due to Amplitude Binning in SPECT. In: 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9. IEEE; 2009. p. 2931-+.
- Le Maitre A, Segars WP, Marache S, Reilhac A, Hatt M, Tomei S, et al. Incorporating patient-specific variability in the simulation of realistic whole-body 18F-FDG distributions for oncology applications. Proceedings of the IEEE. 2009 Jan 1;97(12):2026u201338.
- Smyczynski MS, Gifford HC, Lehovich A, Mcnamara JE, Segars WP, Dey J, et al. Effectiveness of three alternative strategies in reducing the degrading impact ofrespiratory motion on the detection of small pulmonary nodules in SPECT imaging. IEEE Nuclear Science Symposium Conference Record. 2008 Dec 1;3663u20137.
- Dey J, Segars WP, Pretorius PH, King MA. Estimation and correction of irregular respiratory motion of the heart in presence of partial angle effects due to amplitude binning in SPECT. IEEE Nuclear Science Symposium Conference Record. 2008 Dec 1;3656u201362.
- Sun Z, Segars WP, Fishman EK, Brinker JA, Taguchi K. Banding artifact reduction for cardiac CT. IEEE Nuclear Science Symposium Conference Record. 2008 Dec 1;4838u20139.
- Li X, Samei E, Segars WP, Sturgeon GM, Colsher JG, Frush DP. Patient-specific dose estimation for pediatric chest CT. Med Phys. 2008 Dec;35(12):5821u20138.
- Segars WP, Mahesh M, Beck TJ, Frey EC, Tsui BMW. Realistic CT simulation using the 4D XCAT phantom. Med Phys. 2008 Aug;35(8):3800u20138.
- Rahmim A, Dinelle K, Cheng J-C, Shilov MA, Segars WP, Lidstone SC, et al. Accurate event-driven motion compensation in high-resolution PET incorporating scattered and random events. IEEE Trans Med Imaging. 2008 Aug;27(8):1018u201333.
- Rahmim A, Cheng J-C, Dinelle K, Shilov M, Segars WP, Rousset OG, et al. System matrix modelling of externally tracked motion. Nucl Med Commun. 2008 Jun;29(6):574u201381.
- Li CM, Segars WP, Lo JY, Veress AI, Boone JM, Dobbins JT. Three-dimensional computer generated breast phantom based on empirical data. In: Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2008.
- hu N, Cerviu00f1o L, Segars W, Lewis J, Tyagi N, Mundt A, et al. THu2010Du2010AUD Au201008: A Method for Generating Large Datasets of Patient Geometries for Radiotherapy Treatment Planning Studies. In: Medical Physics. 2008. p. 2983u20134.
- Baydush A, Godfrey D, Segars W. SUu2010GGu2010Ju201093: Feasibility Study On Artifact Reduction Using Dual Energy Digital Tomosynthesis. In: Medical Physics. 2008. p. 2700.
- Baydush A, Godfrey D, Segars W. SUu2010GGu2010Ju201094: Feasibility Study On the Efficacy of Dual Energy Cine Imaging in Radiation Therapy for Lung Cancer. In: Medical Physics. 2008. p. 2700.
- Fung GSK, Segars WP, Geschwind JFH, Tsui BMW, Taguchi K. Effect of respiratory motion on abdominal C-arm CT angiography using the 4D NCAT phantom. IEEE Nuclear Science Symposium Conference Record. 2007 Dec 1;6:4536u20138.
- Segars WP, Mori S, Chen GTY, Tsui BMW. Modeling respiratory motion variations in the 4P NCAT phantom. IEEE Nuclear Science Symposium Conference Record. 2007 Dec 1;6:4531u20133.
- Segars WP, Mori S, Chen GTY, Tsui BMW. Modeling respiratory motion variations in the 4D NCAT phantom. IEEE Nuclear Science Symposium Conference Record. 2007 Dec 1;4:2677u20139.
- Lee TS, Segars WP, Tsui BMW. The development and application of a realistic simulation dataset for simultaneous cardiac and respiratory gated ECT/CT. IEEE Nuclear Science Symposium Conference Record. 2007 Dec 1;5:3656u20139.
- Segars WP, Mendonca S, Sturgeon G, Tsui BMW. Enhanced 4D heart model based on high resolution dual source gated cardiac CT images. IEEE Nuclear Science Symposium Conference Record. 2007 Dec 1;4:2617u201320.
- Roper JR, Bowsher JE, Segars WP, Yin F. Onboard SPECT for Biological Target Localization. In: International Journal of Radiation Oncology*Biology*Physics. Elsevier BV; 2007. p. S642u20133.
- Taguchi K, Zhihui S, Segars WP, Fishman EK, Tsui BMW. Image-domain motion compensated time-resolved 4D cardiac CT. Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2007 Oct 15;6510(PART 1).
- Taguchi K, Zhang M, Frey EC, Xu J, Segars WP, Tsui BMW. Image-domain material decomposition using photon-counting CT. Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2007 Oct 15;6510(PART 1).
- Smyczynski MS, Gifford HC, Lehovich A, McNamara JE, Segars WP, Tsui BMW, et al. Impact of respiratory motion on the detection of small pulmonary nodules in SPECT imaging. IEEE Nucl Sci Symp Conf Rec (1997). 2007;5:3241u20135.
- Veress AI, Segars WP, Weiss JA, Tsui BMW, Gullberg GT. Normal and pathological NCAT image and phantom data based on physiologically realistic left ventricle finite-element models. IEEE Trans Med Imaging. 2006 Dec;25(12):1604u201316.
- Taguchi K, Segars WP, Fung GSK, Tsui BMW. Toward time resolved 4D cardiac CT imaging with patient dose reduction; estimating the global heart motion. Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2006 Jun 30;6142 I.
- Segars WP, Taguchi K, Fung GSK, Fishman EK, Tsui BMW. Effect of heart rate on CT angiography using the enhanced cardiac model of the 4D NCAT. Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2006 Jun 30;6142 I.
- Fung GSK, Segars WP, Taguchi K, Fishman EK, Tsui BMW. Development of a computer-generated model for the coronary arterial tree based on multislice CT and morphometric data. Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2006 Jun 30;6142 II.
- Tang J, Segars WP, Tsui BMW. Cardiac motion estimation from gated emission computed tomography images. IEEE Nuclear Science Symposium Conference Record. 2006 Jan 1;5:2688u201394.
- Taguchi K, Segars WP, Kudo H, Frey EC, Fishman EK, Tsui BMW. Toward time resolved cardiac CT images with patient dose reduction: Image-based motion estimation. IEEE Nuclear Science Symposium Conference Record. 2006 Jan 1;4:2029u201332.
- Rahmim A, Cheng JC, Dinelle K, Shilov M, Segars WP, Rousset OG, et al. System matrix modeling of externally tracked motion. IEEE Nuclear Science Symposium Conference Record. 2006 Jan 1;4:2137u201341.
- Segars WP, Mok SP, Tsui BMW. Investigation of equal magnitude respiratory gating in quantitative myocardial SPECT. IEEE Nuclear Science Symposium Conference Record. 2006 Jan 1;4:2107u201310.
- Descourt P, Segars WP, Lamare F, Ferrer L, Tsui B, Bizais Y, et al. RTNCAT (Real Time NCAT): Implementing Real Time physiological movement of voxellized phantoms in GATE. IEEE Nuclear Science Symposium Conference Record. 2006 Jan 1;5:3163u20135.
- Shilov MA, Frey EC, Segars WP, Xu J, Tsui BMW. Optimization of gated liver FDG PET with non-uniform respiration. IEEE Nuclear Science Symposium Conference Record. 2006 Jan 1;4:2594u20136.
- Kindhan P, MacDonald L, Ng L, Alessio A, Segars P, Tsui B, et al. Compensating for patient respiration in PET/CT imaging with the registered and summed phases (RASP) procedure. 2006 3rd IEEE International Symposium on Biomedical Imaging from Nano to Macro Proceedings. 2006 Jan 1;2006:1104u20137.
- Segars WP, Tsui BMW. Effect of respiratory motion in CT-based attenuation correction in SPECT using different CT scanners and protocols. IEEE Nuclear Science Symposium Conference Record. 2005 Dec 1;4:2413u20137.
- Lee TS, Segars WP, Tsui BMW. Study of parameters characterizing space-time Gibbs priors for 4D MAP-RBI-EM in gated myocardial perfusion SPECT. IEEE Nuclear Science Symposium Conference Record. 2005 Dec 1;4:2124u20138.
- He B, Du Y, Song X, Segars WP, Frey EC. A Monte Carlo and physical phantom evaluation of quantitative In-111 SPECT. Phys Med Biol. 2005 Sep 7;50(17):4169u201385.
- Kraitchman DL, Tatsumi M, Gilson WD, Ishimori T, Kedziorek D, Walczak P, et al. Dynamic imaging of allogeneic mesenchymal stem cells trafficking to myocardial infarction. Circulation. 2005 Sep 6;112(10):1451u201361.
- Segars WP, Mahesh M, Beck T, Frey EC, Tsui BMW. Validation of the 4D NCAT simulation tools for use in high-resolution x-ray CT research. Progress in Biomedical Optics and Imaging Proceedings of SPIE. 2005 Aug 25;5745(II):828u201334.
- Song X, Segars WP, Du Y, Tsui BMW, Frey EC. Fast modelling of the collimator-detector response in Monte Carlo simulation of SPECT imaging using the angular response function. Phys Med Biol. 2005 Apr 21;50(8):1791u2013804.
- Lalush DS, Jatko MK, Segars WP. An observer study methodology for evaluating detection of motion abnormalities in gated myocardial perfusion SPECT. IEEE Trans Biomed Eng. 2005 Mar;52(3):480u20135.
- Guerrero T, Zhang G, Segars W, Huang T-C, Bilton S, Ibbott G, et al. Elastic image mapping for 4-D dose estimation in thoracic radiotherapy. Radiat Prot Dosimetry. 2005;115(1u20134):497u2013502.
- Veress AI, Segars WP, Tsui BMW, Weiss JA, Gullberg GT. Physiologically realistic LV models to produce normal and pathological image and phantom data. IEEE Nuclear Science Symposium Conference Record. 2004 Dec 1;7:4231u20135.
- Mok SP, Tsui BMW, Wang Y, Qi Y, Du Y, Segars WP, et al. Development and validation of a Monte Carlo simulation tool for multi-pinhole microSPECT. IEEE Nuclear Science Symposium Conference Record. 2004 Dec 1;6:3440u20134.
- He X, Frey EC, Links JM, Gilland KL, Segars WP, Tsui BMW. A mathematical observer study for the evaluation and optimization of compensation methods for myocardial SPECT using a phantom population that realistically models patient variability. IEEE Transactions on Nuclear Science. 2004 Feb 1;51(1 I):218u201324.
- Segars WP, Tsui BMW, Frey EC, Johnson GA, Berr SS. Development of a 4-D digital mouse phantom for molecular imaging research. Mol Imaging Biol. 2004;6(3):149u201359.
- Lee TS, Segars WP, Tsui BMW. A study of the effect of cardiac gating in myocardial SPECT using the 4D NCAT. IEEE Nuclear Science Symposium Conference Record. 2003 Dec 1;4:2681u20135.
- Segars WP, Tsui BMW, Frey EC, Fishman EK. Extension of the 4D NCAT phantom to dynamic X-ray CT simulation. IEEE Nuclear Science Symposium Conference Record. 2003 Dec 1;5:3195u20139.
- Song X, Frey EC, He X, Segars WP, Tsui BMW. A mathematical observer study for evaluation of a model-based compensation method for crosstalk in simultaneous dual isotope SPECT. IEEE Nuclear Science Symposium Conference Record. 2003 Dec 1;4:2521u20135.
- Garrity JM, Paul Segars W, Knisley SB, Tsui BMW. Development of a Dynamic Model for the Lung Lobes and Airway Tree in the NCAT Phantom. IEEE Transactions on Nuclear Science. 2003 Jan 1;50(3):378u201383.
- Segars WP, Tsui BMW, Da Silva AJ, Shao L. CT-PET Image Fusion using the 4D NCAT Phantom with the Purpose of Attenuation Correction. IEEE Nuclear Science Symposium and Medical Imaging Conference. 2002 Dec 1;3:1775u20139.
- Zhu Z, Tsui BMW, Segars WP. A Simulation Study of the Effect of Gating Scheme on Respiratory Motion Blurring in FDG Lung PET. IEEE Nuclear Science Symposium and Medical Imaging Conference. 2002 Dec 1;3:1554u20138.
- Smyczynski MS, Gifford HC, Farncombe TH, Segars WP, Tsui BMW, King MA. Impact of respiratory motion on the detection of solitary pulmonary nodules with SPECT tumor imaging of NeoTect. IEEE Nuclear Science Symposium and Medical Imaging Conference. 2002 Dec 1;2:838u201341.
- He X, Frey EC, Links J, Gilland KL, Segars WP, Tsui BMW. Evaluation and Optimization of Compensation Methods for Myocardial SPECT using a Set of Realistic Phantoms that Include Patient Variability. IEEE Nuclear Science Symposium and Medical Imaging Conference. 2002 Dec 1;2:764u20138.
- Garrity JM, Segars WP, Knisley S, Tsui BMW. Development of a Dynamic Model for the Lung Lobes and Airway Tree in the NCAT Phantom. IEEE Nuclear Science Symposium and Medical Imaging Conference. 2002 Dec 1;3:1858u201362.
- Hauser MA, Walter JW, Walters RW, Maready M, Takeuchi S, Segars WP, et al. Identification of candidate genes for Parkinson disease (PD)by the convergence of genetic linkage and association data with gene expression in the substantia nigra. In: AMERICAN JOURNAL OF HUMAN GENETICS. UNIV CHICAGO PRESS; 2002. p. 467u2013467.
- Segars WP, Tsui BMW. Study of the efficacy of respiratory gating in myocardial SPECT using the new 4-D NCAT phantom. IEEE Transactions on Nuclear Science. 2002 Jun 1;49 I(3):675u20139.
- Smyczynski MS, Segars WP, Narayanan MV, Pretorius PH, Gifford HC, Farncombe TH, et al. Modeling the respiratory motion of solitary pulmonary nodules for investigating SPECT tumor imaging. IEEE Nuclear Science Symposium and Medical Imaging Conference. 2001 Dec 1;3:1371u20135.
- Segars WP, Tsui BMW. Study of the efficacy of respiratory gating in myocardial SPECT using the new 4D NCAT phantom. IEEE Nuclear Science Symposium and Medical Imaging Conference. 2001 Dec 1;3:1536u20139.
- Segars WP, Lalush DS, Tsui BMW. Modeling respiratory mechanics in the MCAT and spline-based MCAT phantoms. IEEE Transactions on Nuclear Science. 2001 Feb 1;48(1 I):89u201397.
- Faber TL, Garcia EV, Lalush DS, Segars WP, Tsui BMW. Simulating patient-specific heart shape and motion using SPECT perfusion images with the MCAT phantom. Proceedings of SPIE the International Society for Optical Engineering. 2001 Jan 1;4319:22u20136.
- Segars WP, Lalush DS, Tsui BMW. Development of an interactive software application to model patient populations in the 4D NURBS-based Cardiac Torso phantom. IEEE Nuclear Science Symposium and Medical Imaging Conference. 2000 Dec 1;3:20/55.
- Tsui BMW, Segars WP, Lalush DS. Effects of upward creep and respiratory motion in myocardial SPECT. IEEE Transactions on Nuclear Science. 2000;47(3 PART 3):1192u20135.
- Tsui BMW, Segars WP, Lalush DS. Effects of upward creep and respiratory motion in myocardial SPECT. IEEE Transactions on Nuclear Science. 2000 Jan 1;47(3 PART 3):1192u20135.
- Segars WP, Lalush DS, Tsui BMW. Next generation MCAT: A realistic spline-based torso phantom. Annual International Conference of the IEEE Engineering in Medicine and Biology Proceedings. 1999 Dec 1;2:978.
- Lalush DS, Segars WP, Tsui BMW. Monte Carlo optimization of 4D smoothing methods for gated myocardial perfusion SPECT. Annual International Conference of the IEEE Engineering in Medicine and Biology Proceedings. 1999 Dec 1;2:1123.
- Paul Segars W, Lalush DS, Benjamin M, Tsui W. Namic heart phantom. IEEE Transactions on Nuclear Science. 1999 Dec 1;46(3 PART 2):503u20136.
- Segars WP, Lalush DS, Tsui BMW. Realistic spline-based dynamic heart phantom. IEEE Nuclear Science Symposium and Medical Imaging Conference. 1999 Jan 1;2:1175u20138.
- Segars P, McNamee JE. Pattern of vascular resistance contributes to blood flow heterogeneity. FASEB Journal. 1996 Dec 1;10(3):A387.
In The News
- Artemis Launches With Two Duke Experiments (Nov 16, 2022 | )
- Meet Helga and Zohar, Duke's Space Pioneers (Sep 7, 2022 | Pratt School of Engineering)